Cisco 2800 Series |
Cisco 2801 |
Cisco 2811 |
Cisco 2821 |
Cisco 2851 |
|
|
Product Architecture |
|||||
|
DRAM |
• Default: 128 MB
• Maximum: 384 MB
|
• Default: 256 MB
• Maximum: 768 MB
|
• Default: 256 MB
• Maximum: 1 GB
|
||
|
Compact Flash |
• Default: 64 MB
• Maximum: 128MB
|
• Default: 64 MB
• Maximum: 256 MB
|
|||
|
Fixed USB 1.1 Ports |
1 |
2 |
|||
|
Onboard LAN Ports |
2-10/100 |
2-10/100/1000 |
|||
|
Onboard AIM (Internal) Slot |
2 |
||||
|
Interface Card Slots |
• 4 slots; 2 slots support HWIC, WIC, VIC, or VWIC type modules
• 1 slot supports WIC, VIC, or VWIC type modules
• 1 slot supports VIC or VWIC type modules
|
4 slots, each slot can support HWIC, WIC, VIC, or VWIC type modules |
|||
|
Network-Module Slot |
No |
1 slot, supports NM and NME type modules |
1 slot, supports NM, NME and NME-X type modules |
1 slot, supports NM, NME, NME-X, NMD and NME-XD type modules |
|
|
Extension Voice Module Slot |
0 |
1 |
|||
|
PVDM (DSP) Slots on Motherboard |
2 |
3 |
|||
|
Integrated Hardware-Based Encryption |
Yes |
||||
|
VPN Hardware Acceleration (on Motherboard) |
DES, 3DES, AES 128, AES 192, and AES 256 |
||||
|
Optional Integrated In-Line Power (PoE) |
Yes, requires AC-IP power supply |
||||
|
Console Port |
1 |
||||
|
Auxiliary Port |
1 |
||||
|
Minimum Cisco IOS Software Release |
12.3(8)T |
||||
|
Rack Mounting |
Yes, 19-inch |
Yes, 19- and 23-in. options |
|||
|
Wall Mounting |
No |
Yes |
No |
No |
|
|
Power Requirements |
|||||
|
AC Input Voltage |
100 to 240 VAC, autoranging |
||||
|
AC Input Frequency |
47-63 Hz |
||||
|
AC Input Current |
2A (110V) 1A (230V) |
3A (110V) 2A (230V) |
|||
|
AC Input Surge Current |
50A maximum, one cycle (-48V power included) |
||||
|
AC-IP Maximum In-Line Power Distribution |
120W |
160W |
240W |
360W |
|
|
AC-IP Input Current |
4A (110V) 2A (230V) |
8A (110V) 4A (230V) |
|||
|
AC-IP Input Surge Current |
50A maximum, one cycle (-48V power included) |
||||
|
DC Input Voltage |
No DC Power Option available |
24 to 60 VDC, autoranging positive or negative |
|||
|
DC Input Current |
• No DC Power Option available
|
• 8A (24V)
• 3A (60V)
• Startup current 50A<10 ms
|
• 12A (24V)
• 5A (60V)
• Startup current 50A<10 ms
|
||
|
Typical Power Dissipation (No Modules) |
42W (143 BTU/hr) |
32W (109 BTU/hr) |
54W (184 BTU/hr) |
58W (197 BTU/hr) |
|
|
Power Dissipation-AC without IP Phone Support |
150W (511 BTU/hr) |
170W (580 BTU/hr) |
280W (955 BTU/hr) |
280W (955 BTU/hr) |
|
|
Power Dissipation-AC with IP Phone Support-System Only |
150W (511 BTU/hr) |
210W (717 BTU/hr) |
310W (1058 BTU/hr) |
370W (1262 BTU/hr) |
|
|
Power Dissipation-AC with IP Phone Support-IP Phones |
180W (612 BTU/hr) |
160W (546 BTU/hr) |
240W (819 BTU/hr) |
360W (1128 BTU/hr) |
|
|
Power Dissipation-DC |
Not applicable |
180W (614 BTU/hr) |
300W (1024 BTU/hr) |
300W (1024 BTU/hr) |
|
|
RPS |
No |
External only, connector for RPS provided by default |
|||
|
Recommended RPS Unit |
No RPS option |
Cisco RPS-2300 Redundant Power System |
|||
|
Environmental Specifications |
|||||
|
Operating Temperature |
32° to 104°F (0° to 40°C) |
||||
|
Non-Operating Temperature |
-4° to 149°F (-20° to 65°C) |
-40° to 158°F (-40° to 70°C) |
|||
|
Maximum Operating Temperature at Altitude |
• 40°C @ sea level
• 31°C @ 6,000 ft
(1800 m) • 25°C @ 10,000 ft (3000 m)
Note: Derate 1.5°C per 1000 ft |
• 40°C @ sea level
• 40°C @ 6,000 ft
(1800 m) • 30°C @ 13,000 ft (4000 m)
• 27.2°C @ 15,000 ft (4600 m)
Note: Derate 1.4°C per 1,000 ft above 6,000 ft |
|||
|
Operating Humidity |
10 to 85% RH non-condensing |
5 to 85%RH, non-condensing |
|||
|
Dimensions (H x W x D) |
• 1.72 x 17.5 x 16.5 in.
• (43.7 x 445 x 419 mm)
|
• 1.75 x 17.25 x 16.4 in.
• (44.5 x 438.2 x 416.6 mm)
|
• 3.5 x 17.25 x 16.4 in.
• (88.9 x 438.2 x 416.6 mm)
|
||
|
Rack Height |
1 rack unit (1RU) |
2RU |
|||
|
Weight (Fully Configured) |
13.7 lb (6.2 kg) |
14 lb (6.4 kg) |
25 lb (11.4 kg) |
||
|
Noise Level (Min/Max) |
• 39 dBA for normal operating temperature (<90°F/32.2°C)
• 53.5 dBA (@ maximum fan speed)
|
• 47 dBA for normal operating temperature (<90°F/32.2°C)
• 57 dBA (@ maximum fan speed)
|
• 44 dBA for normal operating temperature (<90°F/32.2°C)
• 53 dBA (@ maximum fan speed)
|
||
|
Regulatory Compliance |
|||||
|
NEBS |
No |
Yes |
Yes |
||
|
Safety |
• UL 60950
• CAN/CSA C22.2 No. 60950
• IEC 60950
• EN 60950-1
• AS/NZS 60950
|
||||
|
Immunity |
• EN300386
• EN55024/CISPR24
• EN50082-1
• EN61000-6-2
|
||||
|
EMC |
• FCC Part 15
• ICES-003 Class A
• EN55022 Class A
• CISPR22 Class A
• AS/NZS 3548 Class A
• VCCI Class A
• EN 300386
• EN61000-3-3
• EN61000-3-2
|
||||
|
FIPS-2 |
FIPS 140-2 Certification for 2801, 2811, 2821, 2851 |
||||
|
TELCOM** |
• For all four platforms, Telecom compliance standards depend upon country and interface type. Interfaces comply with FCC Part 68, CS-03, JATE Technical Conditions, European Directive 99/5/EC and relevant TBR's. For specific information see the datasheet for the specific interface card.
• Homologation requirements vary by country and interface type. For specific country information, see the on-line approvals data base:http://tools.cisco.com/cse/prdapp/jsp/externalsearch.do?action=externalsearch&page=EXTERNAL_SEARCH&module=EXTERNAL_SEARCH
|
||||
با استفاده از دکمه سفارش دهی و ارسال درخواست برای فروشنده، می توانید برای خرید این محصول به صورت عمده با فروشنده وارد مذاکره شوید. با پرداخت آنلاین وجه سفارش از ضمانت بازگشت وجه برخوردار می شوید.
ضمانت سلامت فیزیکی
ضمانت اصالت کالا